Better Buildings for a Better World.
COVERTEK 215
Versatile self-supporting synthetic roof underlay.
Jump to feature
Product Specifications
Covertek 215 comes in two roll sizes:
Width | Length | Coverage |
---|---|---|
1350mm wide | 18.6m long | 25m² Coverage* |
1350mm wide | 37m long | 50m² Coverage* |
* Note: m² is the roll size for actual coverage, allow for laps and joins.
Designed for use as a roof underlay within the following scope:
Contributes to meeting the Performance Requirements of NZBC Clauses B2, Durability (B2.3.1 (a) 50 years, B2.3.1 (b) 15 years and B2.3.2), E2 External Moisture E2.3.2) and F2 Hazardous Building Materials F2.3.1, providing:
* Note: specifiers and product user must test for wall cladding system compatibility with the underlay before installation.
In climatic regions where condensation risks are high, such as cold or high humidity areas, care needs to be taken in specifying the correct design and installation to prevent moisture build-up in the roof cavities.
Factors which adversely affect the condensation risk in roofing systems include:
Skillion and Warm Roof Construction are particularly sensitive to moisture accumulation and the design and installation of roof construction needs to take into account the higher condensation risks. Refer to the NZ Metal Roof and Wall Cladding Code of Practice for details.
For passive ventilation of the roof space, it is recommended that all roof underlays are terminated at the ridge, and if not it should be slit or slotted to allow for passive ventilation. For further information refer to the NZ Metal Roof and Wall Cladding Code of Practice.
Standard Thermakraft warranty applies. Refer to Kingspan Insulation Warranty Statement for further details. This item is available online here or call 0800 806 595.
NZBC E2/AS1 Table 23 (NZ2295)Wall Underlay Properties | Absorbency* | Vapour Resistance | pH of Extract | Shrinkage | Water Resistance |
---|---|---|---|---|---|
Property Performance Requirement | ≥ 150gsm | ≤ 7MN.s/g | ≥ 5.5 and ≤ 8 | ≤ 0.5% | ≥ 100mm |
Property Performance | Pass* | Pass | Pass | Pass | Pass |
* Absorbency test done by BRANZ using section 8 of Study Report SR228 (2010).
Related products
Lightweight galvanized steel mesh used to support roofing underlays, foils and insulations. Ausnet is NOT a safety mesh.
Premium roof safety mesh for use in commercial roof applications where falling hazards exist. Comes in Galvanised finish or PVC coating for high corrosive applications (e.g. coastal).
Acrylic adhesive tape that provides excellent bonding to most substrates.
Products/Technical Information
Build Better
Building Systems
Contact
Kingspan Insulation NZ Ltd | All Rights Reserved