Better Buildings for a Better World.
COVERTEK 403
Non self-supporting roof and wall underlay.
Jump to feature
Covertek 403 is a fire retardant, light weight roof and wall underlay designed as a
means of managing condensation, water vapour transfer and water ingress. Primarily developed as a roof underlay, Covertek 403 can also be used on walls if you are after a one stop solution. It is not self-supporting as a roof underlay and is a more affordable option where a supporting component is to be installed in the building.
Product Specifications
Covertek 403 comes in three roll sizes:
Width | Length | Coverage |
---|---|---|
1350mm wide | 18.6m long | 25m² Coverage* |
1350mm wide | 37m long | 50m² Coverage* |
1350mm wide | 56m long | 75m² Coverage* |
* Note: m² is the roll size for actual coverage, allow for laps and joins.
Roof Application
Wall Application
Roof Application
Thermakraft Covertek 403 Underlay has an AS 1530 Part 2 Flammability Index of not greater than 5 and therefore meets the requirements of NZBC Acceptable Solution C/AS2, Paragraph 4.17.8(b), for the surface finish requirements of suspended flexible fabric used as an underlay to exterior cladding that is exposed to view in occupied spaces.
Meets the Performance Requirements of NZBC Clauses B2, Durability (B2.3.1 (a) 50 years, B2.3.1 (b) 15 years and B2.3.2), and F2.3.1, providing:
* Note: specifiers and product user must test for wall cladding system compatibility with the underlay before installation.
In climatic regions where condensation risks are high, such as cold or high humidity areas, care needs to be taken in specifying the correct design and installation to prevent moisture build-up in the roof cavities.
Factors which adversely affect the condensation risk in roofing systems include:
Skillion and Warm Roof Construction are particularly sensitive to moisture accumulation and the design and installation of roof construction needs to take into account the higher condensation risks. Refer to the NZ Metal Roof and Wall Cladding Code of Practice (COP) for details.
For passive ventilation of the roof space, it is recommended that all roof underlays are terminated at the ridge, and if not it should be slit or slotted to allow for passive ventilation. For further information refer to the NZ Metal Roof and Wall Cladding COP.
Standard Thermakraft warranty applies. Refer to Thermakraft Warranty Statement for further details. This item is available online here or call 0800 806 595.
NZBC E2/AS1 Table 23 (NZ2295)Wall Underlay Properties | Absorbency | Vapour Resistance | pH of Extract | Shrinkage | Water Resistance | Air Resistance |
---|---|---|---|---|---|---|
Property Performance Requirement | ≥ 150gsm | ≤ 7 MN.s/g | ≥ 5.5 and ≤ 8 | ≤ 0.5% | ≥ 100mm | ≥ 0.1 MN.s/m3 |
Property Performance | Pass | Pass | Pass | Pass | Pass | Pass* |
* Note: Can be used as an air barrier.
Related products
Lightweight galvanized steel mesh used to support roofing underlays, foils and insulations. Ausnet is NOT a safety mesh.
Premium roof safety mesh for use in commercial roof applications where falling hazards exist. Comes in Galvanised finish or PVC coating for high corrosive applications (e.g. coastal).
Premium synthetic flashing tape providing high adhesion in the harshest conditions.
Bitumin-based, foil backed window flashing tape with high strength bond and excellent abrasion resistance and flexibility.
Used in conjunction with Thermakraft window flashing tapes to provide a robust corner flashing detail.
Products/Technical Information
Build Better
Building Systems
Contact
Kingspan Insulation NZ Ltd | All Rights Reserved